Linseis – Gravimetric Sorption Analysis (GSA)
Integrated solutions that offer the possibility to control the pressure, temperature and gas dosing independently of each other using the supplied software.
Linseis offers two different load cells, a mechanical microbalance and a magnetic levitation balance.
The magnetic levitation balance offers a unique, hermetically sealed measuring cell for highly reactive gases.
There is therefore a large selection of available devices in a temperature range from -196 °C to 2400 °C and a pressure range from ultra-high vacuum to 350 bar.
An optional TG-DSC (Thermogravimetry – Differential Scanning Calorimetry) measuring head enables the simultaneous determination of weight changes and caloric reactions in one measuring run.
IDEAL FOR
Linseis offers the widest range of sorption analyzers for numerous applications such as
- Chemisorption/physisorption (UHV up to 350 bar)
- Adsorption isotherms
- TPD, TPO, TPR measurements (-196 to 1800°C)
- Sorption enthalpies (simultaneous TG/DSC sensor)
- In-situ gas analysis (FTIR, Raman, MS)
- Corrosive atmospheres Magnetic levitation balance
Areas of application:
- Gas sorption analysis
- Sorption enthalpies (simultaneous TG/DSC sensor)
- Density determinations
- Gas storage
- Zeolite
- Catalysts
- In-situ gas analysis (FTIR, Raman, MS)
- Kinetic analysis
- Corrosive atmospheres – Magnetic suspension balance
- Adsorption isotherm (BET Surface Analysis)
- TPD, TPO, TPR measurements (-196°C to 1800°C)
FEATURES
MODEL |
GSA PT 10* |
---|---|
Temperature range: | -150°C to 1600°C |
Sample weight: | up to 5/25/35 g (higher volumes on request) |
Resolution: | 0.025 / 0.1 μg |
Vacuum: | up to 10E-5 mbar |
Pressure: | up to 15 bar |
Sensors: | TG TG – DTA |
Sensor material: | E/K/S/B |
Electronics: | integrated |
Interface: | USB |
MODEL |
GSA PT 100* |
---|---|
Temperature range: | -170°C up to 1250/1400/1600/1800°C |
Pressure range: | max. 150 bar (different versions), 300 bar on request |
TGA: | |
Max. Sample volume: | 2/15g (more on request) |
Resolution: | 0.1 μg |
DSC: | |
DSC Resolution: | 0.3/0.4/1 μW |
DSC Sensors: | E, K, S, C |
Options: | Gas mixing system (MFC’s) |
Atmospheres: | inert, oxidizing, red, vac |
MODEL |
GSA PT 1000 * |
---|---|
Temperature range: | RT up to 1100°C and max. 150 bar RT up to 1400/1800°C and max. 50 bar |
Vacuum: | 10E-4 mbar |
TGA | |
Max. Sample weight: | 2/15/100g |
Resolution: | 0.1/0.5/10 µg |
DSC | |
DSC resolution: | 0.3/0.4/1 µW |
DSC sensor: | E, K, S, C |
DTA | |
DTA sensitivity: | undefined |
Options: | Gas mixing plant |
Atmosphere: | inert, oxidizing**, red, vac. |